Studi Implementasi Directional Earth Fault Protection Pada Proteksi Bay Penghantar 150 KV Garuda Sakti - Teluk Lembu Anggoro, Arief Sandy; Hamdani, Eddy
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 5 (2018): Edisi 2 Juli s/d Desember 2018
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

In order to optimize High Voltage Transmission Line Protection when a phase to ground fault occurs with high resistance value is implemented DEF (Directional Earth Fault) as protection feature on Distance Relay to detect this fault. Directional Earth Fault working method uses 3I0 residual neutral current detection related to zero order or negative sequence and 3V0 neutral voltage so that the DEF operation area is known both direction, minimum current and minimum voltages. High Voltage Transmission Line Protection in section 150 kV Garuda Sakti - Teluk Lembu is implemented DEF through stages of recording data collection of disturbances from previous conditions as reference of high-resistance ground phase conditions for comtrade playback record method, Simulation of transmission conditions and equipment during the disturbance conditions using Digsilent 14.0 study simulation for power system and short circuit circuit analiysis, application of relay protection protocol manufacturer Schneider type Micom P442, and simulation of individual testing using Omicron CMC 356. Each stages of DEF implementation of this study will be fulfilled when the results of simulation succed and final settings implementation on the protection relay with good individual test results.Keywords : DEF, High Resistance, Comtrade.
Rancang Bangun Generator Ozon Koaksial Sulistianto, Agus Ernawan; Murdiya, Fri; Hamdani, Eddy
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 8 (2021): Edisi 1 Januari s/d Juni 2021
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The developmentof science and technology, especially in industry, can have both positive` and negative effects.`One of the negative `effects is the higher pollution in soil, water and air. The use of ozone has now been widely applied in various fields, for example as a disinfectant for drinking water treatment, disinfecting germs, sterilizing medical devices and preserving food ingredients. Ozone can be generated by the dielectric barrier discharge method which is generally used as a method of generating ozone supplied with high voltage or also known as high voltage plasma generators. High voltage plasma occurs in the dielectric barrier discharge air gap due to the failure of air to maintain its insulating properties. The type of electrode used and the gap distance in the dielectric barrier dischrage test can affect the amount of plasma produced, and plasma also affects the yield of ozone concentration. In this research, a coaxial ozone generator will be designed with a variation of 3 inner electrodes, variations in the flow rate of oxygen input and the presence `or absence of the `influence of the magnetic field on` the ozone produced.    Keywords: Science, Ozone, Dielectric Barrier Discharges, Electrodes, Plasma, Magnetic Field.
Pembuatan Penyaring Air Untuk Peternak Ayam Petelur Di Dusun I Kubu Cubadak Simpang Petai Anhar; Nurhalim Nurhalim; Feri Candra; Antonius Rajagukguk; Eddy Hamdani
Jurnal Pengabdian UntukMu NegeRI Vol 5 No 1 (2021): Pengabdian Untuk Mu negeRI
Publisher : LPPM UMRI

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37859/jpumri.v5i1.2241

Abstract

In order to supply the water for laying hens farm in Kubu Cubadak Simpang Petai, the service team from University of Riau has designed a water purification system using the filtration technique. Before designing the filtration, sample of water from the well around the farm is taken and analyzed in the laboratory. Based on this result, the filtration is characterized to get the water satisfying the needs of the farm. There are two tubs in the filtration system containing silica sand, zeolite, and active carbon. Water from the well is pumped to the tank with three-meter height. From there, water is pumped back again to the tube to get the optimal water flow. The quality of water from the filtration have enhancement in terms of color, turbidity, and pH. The color and turbidity of water are improved from 41 NTU to 0 NTU and from 22,5 NTU to 5,59 NTU, respectively. Furthermore, there is an increasing in pH of water, from 5,44 to 6,32. These results have fulfilled the standard for laying hens farm.
Kajian Perancangan Sistem Penangkal Petir Eksternal Pada Gedung Pusat Komputer Universitas Riau Ujang Mulyadi; Edy Ervianto; Eddy Hamdani
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 1, No 2 (2014): Wisuda Oktober Tahun 2014
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Pekanbaru City is a city located in an area that has a large enough lightning density is equal to 136 days per year with thunder, lightning strikes the ground density (Ng) reached 19.5128 strike/km2/year. Computer Center Building University of Riau is the center of Riau University data, built with a size of 47 m x 21 m x 12.4 m. In the design of the external lightning protection on buildings, there are some technical requirements that need to be considered such as; identifying the needs of a lightning protection system based PUIPP, determining the level of protection lightning protection system based on IEC 1024-1-1, finial selection, determination down conductor and grounding system. From the analysis of hazard assessment, which is an interesting area of 10395.41 m² lightning strike, the possibility of building struck by lightning strikes per year with 0,203 lightning protection system efficiency 0.507. Based on data and analysis can then be described in the protected areas of the Computer Center building good front, side, rear and top. The results obtained showed that the Computer Center building has a poor level of efficiency is based on the analysis of the rolling sphere method. Keywords : external lightning protection system
Identifikasi Kegagalan Peralatan Proteksi Pada Jaringan Distribusi PT. Pln Gardu Induk Garuda Sakti Menggunakan Anfis (Adaptive Neural Fuzzy Inference System) Devi Juliana; Eddy Hamdani; Edy Ervianto
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 2, No 2 (2015): Wisuda Oktober Tahun 2015
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The purpose of research is to identification process of faulty protection devices using operating status of circuit breaker. Technique used for the identification process is Adaptive Neuro-Fuzzy Inference System (ANFIS). ANFIS is a method that combines fuzzy logic and neural network. Design ANFIS needs input data in form of voltage, current and operating status of circuit breaker (1 and 0) for training process. Input data produces by output of distribution system simulation in ETAP, meanwhile operating status of circuit breakers in binary numbers, one and zeros are interpreted as operating and non-operating devices, respectively. The training result gives worth accuracy so that can be use for predicting operating status of circuit breaker. If faulty device has been identified so system restoration can be done immediately.Keywords: ANFIS; distribution system; faulty protection devices; circuit breaker
Analisa Pengaruh Sambaran Petir Pada Jaringan Distribusi 13,8 kV di BOB PT. BSP - Pertamina Hulu Bandar Pedada Menggunakan Software ATP-EMTP Rahmad Wahyudi Syaifulloh; Eddy Hamdani
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 4, No 2 (2017): Wisuda Oktober Tahun 2017
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

The purpose of this paper is to analize the effect of indirect lightning strikes on the 13.8 kV distribution network at BOB PT. BSP - Pertamina Hulu Bandar Pedada by using ATP-EMTP. Maximum induced voltage of indirect lightning is computed by using Rusck theory, then indirect lightning strikes are simulated by using ATP-EMTP. In this paper, five conditions are simulated. The first condition is the distribution line without the indirect lightning strikes with 15 kV lightning arresters and the ground wire is installed, the second condition is the indirect lightning strikes without the 15 kV lightning arresters and ground wire, the third condition is indirect lightning strikes with the ground wire is installed and without the 15 kV lightning arrester, the fourth condition is the indirect lightning strikes with 15 kV lightning arresters are installed and without the ground wire, and the fifth condition is the indirect lightning strikes with the 15 kV lightning arresters and ground wire is installed. The simulation results show that the ground wire is able to reduce the effect of the induced voltage from the indirect lightning strikes, the 15 kV lightning arresters are able to reduce the effect of the induced voltage from the indirect lightning strikes, and the best results are obtained when the ground wire and the 15 kV lightning arresters are installed on the distribution line.Keyword : Indirect lightning strikes, Rusck theory, lightning arresters, ground wire, medium voltage distribution line.
Evaluasi Sistem Proteksi Petir Pada Tower Pt. Sampoerna Telekomunikasi Indonesia (Ceria) Pekanbaru Febriani Syafran Putri; Eddy Hamdani
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 4, No 1 (2017): Wisuda Februari Tahun 2017
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Lightning occurs because there is a difference of potential between the cloud and the earth or by other clouds. Lightning caused a lot of harm to people and damage to the equipment. Some places with the high rate of lightning strikes (frequency and intensity) of being the first priority in the use of the installation of lightning protection. Tropical countries like Indonesia generally have a high lightning day each year, including in the area of Pekanbaru. This paper proposes to evaluate lightning protection system in PT. Sampoerna Telekomunikasi Indonesia (Ceria) Pekanbaru. Improvement of lightning protection system is made through a Rolling Sphere Method. The result of the data shows that the lightning protection system in PT. Sampoerna Telekomunikasi Indonesia (Ceria) Pekanbaru was already capable of protecting the Base Station Transceiver (BTS) from lightning strikes. This results is proven to indicate that lightning protect is improved.Keywords: lightning protection system, Rolling Sphere Method, lightning protection system in PT. Sampoerna Telekomunikasi Indonesia (Ceria) Pekanbaru
Koordinasi Rele Pada Jaringan Transmisi 150 kV Anharul Azmi; Eddy Hamdani
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 3, No 2 (2016): Wisuda Oktober Tahun 2016
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Power transmission system is of one component in the supply of electricity. Then it takes one of transmission system good. To maintain of transmission system good needed protection system accordance with the requirements of protection . protection system functioning of to localize disturbance as small as possible . protection system of transmission normally using of distance relay and OCR-GFR relay. distance relay serves as a main security and OCR-GFR for as backup. calculation of short circuit and relay coordination using digsilent program 14.1.3. based on the results of calculations and simulations showed that the distance relay coordination is good and necessary for resetting the relay OCR-GFR due to changes in short circuit.Keywords: transmission, coordination, distance relay, ocr-gfr relay, ETAP
Konsep Desain Reaktor Termonuklir Fusi Tokamak Sizeable Sebagai Sumber Daya Pembangkit Listrik Tenaga Nuklir Dengan Pengamanan Cryogenic Dheo Erfiansyah; Yusnita Rahayu; Eddy Hamdani
Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains Vol 6 (2019): Edisi 1 Januari s/d Juni 2019
Publisher : Jurnal Online Mahasiswa (JOM) Bidang Teknik dan Sains

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Some implications and research about tokamak as nuclear fusion reactor are examined. From the other researching about tokamak shown that this nuclear fusion reactor has been developed significantly in last 3 decade. In this research to determine new concept to recreate the tokamak with more safety tendencies. The step from this idea to make tokamak is calculate the nuclear fusion cylce energy (based on electron-volt), magnetic field needed (e.m.u), the equilibrium value of nuclear reaction (in electron-volt), temperature and heat conversion of the result from fusion reaction. Also, as the measurement of the tokamak, this study using sizeable value to determine radius of orbit, the coil, etc. From the conclusion this tokamak concept has estimate to produced high energy and high temperature. The tokamak projected to have >200MeV equilibrium energy value and converted to heat energy around 500°C - 600°C. Which use as the fuel flowed to the boiler as a device to produce steam. Then steam will set in motion the turbine.Keywords: Nuclear Fusion, Tokamak, Equilibrium, Deuterium, Cryogenic
Perancangan Konverter DC ke DC untuk Menstabilkan Tegangan Keluaran Panel Solar Cell Menggunakan Teknologi Boost Converter Suwitno Suwitno; Yusnita Rahayu; Rahyul Amri; Eddy Hamdani
JET (Journal of Electrical Technology) Vol 2, No 3 (2017): JET (Journal of Electrical Technology) Edisi Oktober
Publisher : JET (Journal of Electrical Technology)

Show Abstract | Download Original | Original Source | Check in Google Scholar

Abstract

Efforts and strategies have been done both by the providers of electrical energy and the government to handle the increase in electricity demand.  However, there has been no satisfactory result. The government has set a major policy on energy management, namely conservation and energy diversification in order to reduce dependence on non-renewable energy sources and utilize renewable energy available in areas where power plants will be built to meet the growing demand for electricity. Riau Province in addition to located in tropical climates and many of its areas are on the coast that its existence is very far for affordable network of PLN electricity, therefore the provision of solar power plant is one appropriate alternative, to meet the needs of electrical energy for the needs of the population. While the output voltage generated by solar cells is not constant, but it depends on the natural conditions that at any time vary the intensity of sunlight, so that the output voltage of the solar cell is also not constant and varies throughout the daytime. In general, commercial equipment has specification limits for ± 10% voltage variation. Disturbances such as voltage varization, if not handled seriously can cause damage to consumer electrical equipment, in addition to the use of electrical energy, in the form of varying output voltage resulting in expensive cost. To overcome the problem of voltage variations produced solar cell can be used prototype dc to dc converter using boost converter technology, which  automatically  adjust  the  output  voltage  according  to  the  desired  voltage.Designing  DC  to  DC Converters To Stabilize Solar Cell Outputs Using Boost Converter Technology has been tested for performance through the output voltage of a 100 WP solar cell panel whose values vary from 13.5 volts to 20.8 volts as a boost converter input and produce a regulated output voltage 24 volt. Based on the results of prototype testi ng dc to dc converter using booast converter technology that has been designed to produce a voltage regulated voltage of 24 volts direct current declared valid. The valid intent here because the output voltage is still dirange 24 volts ± 10%.