Claim Missing Document
Check
Articles

Found 4 Documents
Search

Load characteristic analysis of a double-side internal coreless stator axial flux PMG Wirtayasa, Ketut; Irasari, Pudji; Kasim, Muhammad; Widiyanto, Puji; Hikmawan, Muhammad Fathul
Journal of Mechatronics, Electrical Power and Vehicular Technology Vol 10, No 1 (2019)
Publisher : Research Centre for Electrical Power and Mechatronics, Indonesian Istitutes of Sciences

Show Abstract | Download Original | Original Source | Check in Google Scholar | Full PDF (2867.192 KB) | DOI: 10.14203/j.mev.2019.v10.17-23

Abstract

The main issue of using a permanent magnet in electric machines is the presence of cogging torque. Several methods have been introduced to eliminate it, one of which is by employing a coreless stator. In this paper, the load characteristic analysis of the double-side internal coreless stator axial flux permanent magnet generator with the specification of 1 kW, 220 V, 50 Hz, 300 rpm and 1 phase is discussed. The purpose is to learn the effect of the load to the generator performance, particularly the output power, efficiency and voltage regulation. The design and analysis are conducted analytically and numerically with two types of simulated loads, pure resistive and resistive-inductive in series. Each type of load provides power factor 1 and 0.85 respectively. The simulation results show that when loaded with resistive load, the generator gives a better performance at the output power (1,241 W) and efficiency (91 %), whereas a better voltage regulator (5.86 %) is achieved when it is loaded with impedance. Since the difference in the value of each parameter being compared is relatively small, it can be concluded that the generator represents good performance in both loads.
Torque Characteristic Analysis of Outer Rotor Permanent Magnet Generator for Low Head Hydro Power Application Irasari, Pudji; Hikmawan, Muhammad Fathul; Widiyanto, Puji
Jurnal IPTEK Vol 23, No 2 (2019)
Publisher : LPPM Institut Teknologi Adhi Tama Surabaya (ITATS)

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.31284/j.iptek.2019.v23i2.524

Abstract

This paper analyzes the torque characteristics of outer rotor PMG for low head hydro power application. The aim is to prevent the generator torque from exceeding the turbine torque as the prime mover so that the system can work properly in both start and steady state conditions. The PMG is of outer rotor type and the torques are calculated analytically and numerically. The analysis is focused only on the PMG without connecting it to the turbine. Two analyzed torques include electromagnetic torque and starting torque, which comprises cogging torque, hysteresis torque and friction torque. The electromagnetic torque was obtained by loading the PMG with resistance and impedance (RL-LL in series) respectively. The results indicate that electromagnetic torque is the highest among all the investigated torques although its value is only 5.6% of the turbine torque, and cogging torque is the highest among the starting torque. From those results, it can be concluded that the hydro turbine torque can overcome the generator torque both at start and steady state conditions.
Design of switched reluctance motor as actuator in an end-effector-based wrist rehabilitation robot Azhari, Budi; Hikmawan, Muhammad Fathul; Nugraha, Aditya Sukma; Yazid, Edwar; Pakha, Aji Nasirohman; Baskoro, Catur Hilman Adritya Haryo Bhakti; Rahmat, Rahmat; Ramadiansyah, Mohamad Luthfi
Journal of Mechatronics, Electrical Power, and Vehicular Technology Vol 15, No 2 (2024)
Publisher : National Research and Innovation Agency

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.55981/j.mev.2024.1109

Abstract

The non-communicable diseases have become the top cause of global mortality. One of them is stroke, which also become the first cause of disability worldwide. To help rehabilitate the upper extremities function of stroke survivors, a rehabilitation aid robot is developed, also to bridge the gap between patient and medical staff numbers. An end-effector-based rehabilitation robot is one proposed device. In this case, a switched reluctance motor (SRM) can be utilized as the actuator for its simplicity, robustness, high low-speed torque, and low cost. Thus, this paper proposes a design of SRM to be used as the actuator of an end-effector-based wrist rehabilitation robot. The proposed design is made based on the required torque. To extract the outputs, calculation and simulation using finite element magnetic FEMM 4.2 are conducted. The results show that the SRM produces enough torque, according to references. Moreover, rotor tooth width reduction is not preferred, as it increases the negative torque even though it raises the saliency ratio and cuts the mass of the motor.
Desain dan Simulasi GMP Fluks Aksial Berbasis Dimensi Magnet Permanen Komersil IRASARI, PUDJI; WIDIYANTO, PUJI; HIKMAWAN, MUHAMMAD FATHUL
ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika Vol 8, No 3: Published September 2020
Publisher : Institut Teknologi Nasional, Bandung

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.26760/elkomika.v8i3.602

Abstract

ABSTRAKMakalah ini membahas desain dan simulasi generator magnet permanen fluks aksial 500 W, 220 V, 500 rpm, 1 fasa, stator tunggal tanpa inti besi lunak dan rotor ganda berbahan baja karbon. Tujuan studi adalah untuk mengetahui performa generator pada dua jenis pembebanan yaitu beban RL dan ZL. Metode perhitungan desain dilakukan secara analitik dan numerik menggunakan perangkat lunak FEMM 4.2 dengan berbasis pada dimensi magnet permanen komersil. Performa generator yang dianalisis meliputi tegangan terminal, daya keluaran dan efisiensi. Hasil simulasi menunjukkan bahwa ketika diberi beban RL, daya keluaran dan efisiensi generator lebih tinggi dibanding ketika diberi beban ZL. Grafik tegangan terminal dari kedua jenis pembebanan tersebut sebagian berimpit tetapi pada beban RL tingkat penurunannya lebih tajam disebabkan tegangan jatuhnya lebih besar. Dari semua hasil perhitungan dan simulasi, dapat disimpulkan bahwa generator menunjukkan performa yang baik pada kedua jenis pembebanan dengan efisiensi sekitar 80%.Kata kunci: generator, magnet permanen, fluks aksial, stator tunggal, rotor ganda ABSTRACTThis paper discusses the design and simulation of 500 W, 220 V, 500 rpm axial flux permanent magnet generators, with the construction of coreless, single stator, and double rotor made of carbon steel. This study aims to find out the performance of the generators in two types of loadings, namely RL and ZL loads. The design calculation method is done analytically and numerically using FEMM 4.2 software based on the dimensions of commercial permanent magnets. The generator performances analyzed include the terminal voltage, the output power, and the efficiency. From the simulation results, it is known that under load RL, the output power and efficiency are higher than under load ZL. The terminal voltage graphs of the two types of loadings partially coincide but at the RL load, the rate of the decline is sharper due to the greater voltage drop. From all the results, it can be concluded that the generator shows good performance on both types of loads with a quite high efficiency, which is around 80%.Keywords: generator, permanent magnet, axial flux, single stator, double rotor