Analisis Tingkat Keandalan Pada Jaringan Express Feeder SUTM A3CS Sebagai Incoming Baru Fauzi Fauzi; Subhan Subhan; Muliadi Muliadi; Syukri Syukri; Teuku Murisal Asyadi; Arief Setya Budi
Jambura Journal of Electrical and Electronics Engineering Vol 5, No 1 (2023): Januari - Juni 2023
Publisher : Teknik Elektro - Universitas Negeri Gorontalo

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.37905/jjeee.v5i1.17006

Abstract

Salah satu parameter dalam penyaluran energi listrik adalah mutu dan kehandalan yang harus memenuhi standar. Pada praktiknya, Perusahaan Listrik Negara (PLN) akan terus memperbaiki dan meningkatkan mutu dan kehandalan jaringan listrik guna memberikan pelayanan terbaik bagi setiap pelanggan. Langkah yang diambil salah satunya yang dilakukan oleh Unit Layanan Pelanggan (ULP) Panton Labu, yaitu dengan membangun jaringan baru agar dapat melayani beban yang semakin meningkat. Pembangunan jaringan baru dilakukan supaya dapat memperbaiki tegangan sistem melalui pembagian beban penyulang serta meningkatkan kehandalan dalam mempermudah manuver ketika terjadi gangguan. Kondisi kelistrikan ULP. Panton Labu disuplai dari Gardu Induk (GI) Panton Labu terdiri dari 2 Trafo Daya (TD) yang masing masing berkapasitas 30 MVA. Beban puncak GI. Panton Labu adalah sebesar 14,5 MW untuk TD 1 dan 6,5 MW untuk TD 2. GI. Panton Labu salah satunya mensuplai Gardu Hubung (GH) Panton Labu melalui penyulang PL 05. Namun, sebelumnya hanya terdapat 1 incoming yang masuk ke GH. Panton Labu, padahal pada TD 2 GI. Panton Labu masih terdapat 3 kubikel cadangan (spare) yang belum termanfaatkan dan juga pada kubikel di GH. Panton Labu sudah terdapat couple bus dan 1 kubikel cadangan. Hal ini disebabkan karena belum adanya jaringan express feeder yang menyuplai dari GI. Panton Labu ke GH. Panton Labu sehingga apabila terjadi gangguan pada suplai utama penyulang PL 05 maka akan terjadi padam diseluruh kubikel GH. Panton Labu. Tujuan dari penelitian ini yaitu untuk mendapatkan nilai SAIDI dan SAIFI sebelum dan setelah pembangunan express  feeder SUTM A3CS 3x240 mm2 sebagai incoming baru. Hasilnya, Mutu tegangan pada GH Panton Labu sebelumnya sebesar 20,4 kVterjadi perbaikan menjadi 20,7 kV. Rekonfigurasi express feeder SUTM 3x240 mm2 sebagai incoming baru dapat mengurangi durasi padam dengan indeks keandalan rata rata nilai SAIDI pada ULP. Panton Labu turun dari 12,558 menit/pelanggan menjadi 6,205 menit/pelanggan. One of the parameters in the distribution of electrical energy is the quality and reliability that must meet the standards. In practice, the State Electricity Company (PLN) will continue to improve and increase the quality and reliability of the electricity network to provide the best service for each customer. One of the steps the Panton Labu Customer Service Unit (ULP) takes is to build a new network to serve the increasing load. The construction of a new network is carried out to improve the system voltage by sharing the feeder load and increasing reliability in facilitating maneuvers when disturbances occur. ULP electrical conditions. Panton Pumpkin is supplied from the Panton Pumpkin Substation (GI) consisting of 2 Power Transformers (TD), each with a capacity of 30 MVA. GI peak load. Panton Pumpkin is 14.5 MW for TD 1 and 6.5 MW for TD 2. GI. One is Panton Labu supplying the Panton Labu Switching Station (GH) via a PL 05 feeder. However, previously there was only 1 incoming to GH. Panton Pumpkin, even though at TD 2 GI. Panton Pumpkin still has 3 spare cubicles that have not been utilized and also in cubicles at GH. Panton Pumpkin already has a couple of buses and 1 extra cubicle. This is because there is no express feeder network that supplies from GI. Panton Pumpkin to GH. Panton Pumpkin so that if there is a disturbance to the main supply of the PL 05 feeder, there will be blackouts throughout the GH cubicles. Pumpkin Pantone. The purpose of this study is to obtain SAIDI and SAIFI values before and after the construction of the A3CS A3CS 3x240 mm2 express feeder as a new incoming. As a result, the voltage quality at the previous Panton Pumpkin GH was 20.4 kV, an improvement became 20.7 kV. Reconfiguring the SUTM 3x240 mm2 express feeder as a new incoming can reduce the blackout duration with the reliability index of the average SAIDI value on the ULP. Panton Pumpkin decreased from 12,558 minutes/subscriber to 6,205 minutes/subscriber..
Perbaikan Tegangan Ujung Pada Jaringan Distribusi 20 kV Di GH Tangse ULP Beureunuen Subhan Subhan; Fauzi Fauzi; Teuku Murisal Asyadi; Syukri Syukri; Muliadi Muliadi
Jurnal Teknologi Terpadu Vol 11, No 1 (2023): JTT (Jurnal Teknologi Terpadu)
Publisher : Pusat Penelitian dan Pengabdian Kepada Masyarakat

Show Abstract | Download Original | Original Source | Check in Google Scholar | DOI: 10.32487/jtt.v11i1.1570

Abstract

Jaringan sistem distribusi tenaga listrik merupakan media untuk mendistribusikan energi listrik baik ke industri, maupun pelanggan rumah tangga. Bertambahnya pertumbuhan penduduk maka pengguna atau pelanggan energi listrik juga bertambah sehingga dapat berdampak terhadap pembebanan pada setiap transformator distribusi. Kondisi jaringan distribusi yang tidak optimal akan mengakibatkan pelayanan yang kurang efektif, karena akibat terjadinya jatuh tegangan. Permasalahan yang dihadapi sekarang adalah ketika beban puncak tegangan yang sampai pada GH Tangse sebesar 17,9 kV dengan keadaan SG-11 yang menyuplai untuk 2 penyulang yaitu penyulang kota tangse dan penyulang geumpang dengan beban puncak 2,4 MW dan memiliki 70,72 kms dari GI Sigli. Penambahan Incoming SG-14 dan pengalihan beban pada Incoming SG-14 maka mampu mencukupi suplai beban yang ada pada 2 penyulang kota tangse dan penyulang geumpang, tegangan terima pada Gardu Hubung Tangse menjadi baik dan menaikkan tegangan dari 17,900  kV menjadi 19,760 kV pada SG-11 dengan melakukan perhitungan menggunakan software E-tap.