An Article on Electrical Safety
Abstract
Risk in electrical work is more than any other job even using household purposes, its needs some precaution. Any slippage has no excuse. Fatal incident of a person will create a void place in his organization and family too. We can assume that working in electrical system is similar to that of work in war field. Those who are involved in electrical job they should be alert for each and every second. Mistake or failure will not be any of any excuse. Electricity is blunt and rude.In present paper we would like to enlighten some important areas which need special attention and also create awareness among the people who are working or using electrical power systems. This article is an attempt to cover most of the sub-titles of the paper.
FAQs
AI
What explains the increased danger of AC voltage over DC voltage?
The study reveals that AC voltage can reach peak values of 325.27V, making it 100 times more likely to cause electric shocks compared to 230V DC under similar conditions.
How does soil resistivity affect electrical grounding systems?
Research indicates that lower soil resistivity can significantly enhance grounding system effectiveness, reducing ground resistance requirements, while poor conditions necessitate more complex grounding solutions.
What are the recommended specifications for lightning arresters?
Lightning arresters should have earthing resistance lower than one ohm and utilize separate earth conductors for each phase to prevent operational failure during surge conditions.
What methodology is used to measure soil resistance effectively?
The Fluke 1625 Soil Resistivity Test Meter employs Ohm's Law, measuring voltage drops across strategically placed ground stakes to calculate soil resistance accurately.
When should GFCI protection be implemented according to safety guidelines?
GFCI protection is mandated for all electrical circuits on construction sites and is highly recommended for temporary wiring to prevent electric shocks.
References (12)
- Doherty, M. (2011), 'Workplace Electrical Safety Standard, CSA Z462-08', Electrical Safety Workshop (ESW), 2011 IEEE IAS, 25-28 Jan. 2011, IEEE, pp. 1 - 4.
- Becker, T. (2010), 'Measuring performance of your Electrical Safety Program by audit', Petroleum and Chemical Industry Conference (PCIC), 2010 Record of Conference Papers Industry Applications Society 57th Annual, San Antonio, 20-22 Sept. 2010, IEEE, pp. 1 - 10.
- Croft, E., Summers, W., and Hartwell, F. P. (1953), Electrical Safety in the Workplace, 7th Ed, McGraw- Hill, New York, pp. 51-70.
- Doughty, R. L., Epperly, R. A., and Jones, R. A. (1991), 'Maintaining Safe Electrical Work Practices in a Competitive Environment', Industry Applications Society Annual Meeting, 1991., Conference Record of the 1991 IEEE, Vol. 2, 28 Sep 1991-04 Oct 1991, IEEE, pp. 1275 -1283.
- Kumbhar, N. R., and Joshi, R. R. (2012), 'An Industrial Energy Auditing: Basic Approach', International Journal of Modern Engineering Research, Vol. 2, No. 1, pp. 313-315.
- Roberts, D. T. (2014), 'Integrating OHSMS, Risk Management & Electrical Safety', Electrical Safety
- Workshop (ESW), 2014 IEEE IAS, San Diego, CA., 4- 7 Feb. 2014, IEEE, pp. 1-8.
- Roberts, D. T. (2013), 'Risk Management of Electrical Hazards', IEEE IAS Applications Magazine, Vol. 19, No. 3, p. 21.
- Sivaprakash, P. and Elangovan, R. K. (2013), 'A Study on Safety Audit System in Indian Engineering Industries', Life Science Journal, Vol. 10 (9(s)), pp. 236-240.
- IEEE Standards 1584-2002, IEEE Guide for Performing Arc-Flash Hazard Calculations New York, NY: IEEE.
- M.Wactor, et.al., 'Strategies for Mitigating the effects of Internal Arcing Fault in Medium Voltage, Metal Enclosed switch gear, " Proceeding of IEEE Transmission and Distribution conference and exposition vol. 1, pp 323-328, Oct / Nov 2001
- IEEE C37.20.7 2001 Guide for Testing Medium- Voltage Metal-Enclosed Switchgear for Internal Arcing Faults, New York, NY: IEEE